Specifications PreciCura LR Hot
|
PERFORMANCE
|
Metric
|
US
|
|
Stand off
|
650-2000 mm (Customized)
|
25.6"-78.7" Customized)
|
|
Measurement range (MR)
|
300-8000 mm (Customized)
|
11.8"-315" (Customized)
|
|
Resolution (MR<320 mm)
|
0.01 mm
|
0.001"
|
|
Resolution (320<MR>3200 mm)
|
0,1 mm
|
0.01"
|
|
Resolution (MR>3200 mm)
|
1 mm
|
0,1 "
|
|
Repeatability close end*
|
0.12 mm
|
0.0047"
|
|
Repeatability far end*
|
1.50 mm
|
0.059"
|
|
Sample speed
|
2 kHz
|
|
Detector type
|
CCD
|
|
Power supply
|
18-36 VDC
|
|
LASER
|
|
|
Wavelength
|
635-670 nm
|
|
Laser power
|
5mW up to 20 mW
|
|
Laser class
|
3R, 3B
|
|
Exposure time
|
3 – 2000 µs
|
|
Enclosure
|
|
|
Dimension
|
303x149x57 mm
|
13.03x5.83x2.2"
|
|
Weight
|
3.0 kg
|
6.6 lbs
|
|
Protections class
|
IP 65
|
|
Operating temperature
|
0 .. +40 °C
|
32 .. +104 °F
|
|
Storage temperature
|
-20 °C .. +70 °C
|
-4 °F .. +158 °F
|
|
Material
|
Laquered aluminium
|
|
Interfaces
|
|
|
Service interface
|
RS232
|
|
HOST Interface
|
RS232
|
|
CAN-bus
|
up to 1Mbit/s
|
|
Analogue
|
0-20 mA, 4-20 mA
|
|
Synchronisation interface
|
Synchronizes the exposure time
|
|
Functions/Features
|
|
|
Measuring algorithm
|
Triangulation with modified "centre of gravity". Suppression of background light and second reflections.
|
|
Measurement functions
|
Distance
Distance+offset
Thickness
|
|
Filtering
|
Average 1..1000
Average selftrig
Average trig
Moving average
Average gate
Median 1..1000
Median trig
Median selftrig
Median gate
Adjustable median (0-100%)
|
* For a sensor with standoff= 600 mm and measurement range=3000 mm. Please, contact LIMAB for information about other sensor constellations.