LIMAB

PreciCura SR System hot

Specifications PreciCura SR System Hot

PERFORMANCE

Metric

US

Stand off

100 mm

3.9"

Measurement range

200 mm

7.9"

Resolution

0.01 mm

0.001"

Repeatability close end

0.03 mm

0.0012"

Repeatability far end

0.05 mm

0.0020"

Sample speed

2 kHz

Detector type

CCD

Power supply

18-36 VDC

LASER

 

Wavelength

635-670 nm

Laser power

< 5 mW

Laser class

3R

Exposure time

3 – 2000 µs

Enclosure

 

Dimension

175x108x42 mm

6.89x4.25x1.65"

Weight

1.0 kg

2.2 lbs

Protections class

IP 65

Operating temperature

0 .. +40 °C

32 .. +104 °F

Storage temperature

-20 °C .. +70 °C

-4 °F .. +158 °F

Material

Lacquered aluminium

Interfaces

 

Service interface

RS232

CAN-bus

up to 1 Mbit/s

Synchronisation interface

synchronizes the exposure time

Functions/Features

 

Measuring algorithm

Triangulation with modified "centre of gravity". Suppression of background light and second reflections.

Measurement functions

Distance

Distance+offset

Thickness

Filtering

Average 1..1000

Average selftrig

Average trig

Moving average

Average gate

Median 1..1000

Median trig

Median selftrig

Median gate

Adjustable median (0-100%)